The following is a list of critical bugs or important limitations that users should be aware of which affect MicroSurvey CAD 2027. It is not intended as an exhaustive list of all issues.
Important Note: If you ever experience a crash when using MicroSurvey CAD, when you are asked if you would like to send an error report, please always select Yes to send the report. MicroSurvey and IntelliCAD programmers can use these error reports to help investigate and fix crashing problems that occur within the program, even if it is a problem that is not easily reproducible. Please note the crash reports are not actively monitored for technical support purposes.
Please contact technical support if you experience any problems.
Reported: Jul 30, 2026
Problem: Running the Volume by Entity results in the command line: Unable to recognize command "_MASSPROP". Please try again.
Workaround: Run the CUI command. In the Customize User Interface dialog, expand under ICAD > ALIASES. There is one for VOLUME, delete it. Then press APPLY and OK.
Status: Will be fixed in a future update.
Reported: Aug 5, 2026
Problem: The Properties panel will be closed on reopen of the program, regardless if it was last set to open or hidden from last session.
Workaround: Edit the following file in Notepad: C:\Program Files\MicroSurvey\MSCAD2027\icad.lsp
In there, add an extra line at the bottom as: (command "._PROPERTIES")
Then save and close the file. You may need Admin Rights to edit that icad.lsp file.
Status: Will be fixed in a future update.
Reported: Jan 19, 2026
Problem: Creating text using the Leroy tool does not always apply the correct style. If, for example, you use the Leroy function to:
- create Complex 60 text
- create Leroy 60 text
- create Complex 60 text
...the Complex 60 text style CI060 won't be used in the third step
Workaround: 1. Ensure that you have set Drawing Scale Factor to the intended plot scale. Use ms_rescale if you need to change it.
2. Create "samples" of each of the leroy text styles in a working area off to the side. These can be deleted once this is done. 3. Activate the Text toolbar and use it to select the desired Leroy style and pick on the text, dtext or mtext functions to create new text
Status: Will be fixed in a future update.