Start a conversation

Using Zeno Connect to Configure a Handheld Device to Connect with FieldGenius

The Leica Zeno range of devices are popular for use with MicroSurvey FieldGenius for Windows and Android.  See below for configuration information:


Leica Zeno with FieldGenius for Android:

Link to the Quick Start Guide


Leica Zeno with FieldGenius for Windows:

There is a range of devices distributed by Leica which are used primarily for GIS data collection. FieldGenius can be configured to connect with these devices.  The utility "Zeno Connect" will be required to configure the communications properly.  Here are the steps to follow:

(This article was recently updated for FieldGenius 8, which allows users to choose COM ports larger than 10)

 


Steps to Follow in Zeno Connect:

  • Run Zeno Connect on your device
  • Connect to the GNSS Receiver (if it is an external device)
  • in the Antenna Settings tab of the GNSS Settings select the device you would like FieldGenius to connect to:

  • Switch to the NMEA tab and configure the message interval settings as shown below.  NOTE: Leave the NMEA tab to what comes up by default if the 1s intervals prove problematic.
  • In addition, take note of the "Output Port" that is currently selected.  In this example we can see that COM6 is the current port:
  • NOTE: Zeno Connect must be left running in the background in order for a successful connection to be established in FieldGenius

GNSS Setting Com Port

 


Steps to Follow in FieldGenius:

  • Run FieldGenius
  • Open the FG Sample or start a new project
  • When you see the "Instrument Selection" dialog select the "GNSS Rover" radio button
  • Pick Add, type a name for the profile you are creating and pick Save
  • Pick Edit
  • Pick on "Active Tolerance" and set it to "Autonomous" (this will simplify testing)
  • Pick Model and Communication and configure all options as below
  • Set the Port value to match the number that you noted in "Output Ports" in Zeno Connect.  COM6 is shown as an example:
  • Pick "Connect" to test.  You're finished.

Mod and Com ZRover

  •  Some users have reported that the Leica Zeno Connect driver must be used in place of NMEA Basic


*If a geoid file is to be applied to the current project only apply it in EITHER FieldGenius or Zeno Connect (not both).


IMPORTANT NOTE: Caution field users that they must not modify the Zeno profile while running FieldGenius, or it will not be able to connect until the above steps are repeated.


Other Information:

  • While Zeno connect can report a wide range of NMEA message types, the FieldGenius NMEA driver only supports a narrow range of NMEA messages.  All unsupported messages will simply be ignored by the software.  See this article for more details.
  • FieldGenius reads only the Latitude, Longitude and Ellipsoid height from the GNSS receiver, so any coordinate system or geoid height definitions must be entered in FieldGenius.
  • See this section of the FieldGenius movies page to see how to use FieldGenius for GIS data collection.
Choose files or drag and drop files
Was this article helpful?